What changed for site safety reporting in 2025–2026

Three rule sets that govern site safety reporting have been updated or newly applied in the past 18 months:

  • ICH E6(R3) came into effect in the EU on 23 July 2025. Section 2.7.2 keeps the investigator's duty to report serious adverse events (SAEs) to the sponsor immediately, with a causality assessment.
  • The UK's amended Clinical Trials Regulations took full effect on 28 April 2026. The MHRA's safety reporting guidance, last updated in July 2026, is now final (MHRA, Collection, verification and reporting of safety events).
  • FDA moved IND safety reports to electronic E2B(R3) submission from 1 April 2026. That changes the sponsor's systems, but it puts more weight on complete, timely data from sites.

The MHRA guidance states the core site obligation plainly. The investigator must report all SAEs to the sponsor immediately, except those the protocol or Investigator's Brochure exempts. That report should never take more than 24 hours from knowledge of the event.

The sponsor's 7-day and 15-day regulatory clocks start from the site's report. Every requirement below affects whether the sponsor can meet them.

7 adverse event reporting requirements for site teams

1. Report SAEs to the sponsor immediately, and never later than 24 hours

In the US, 21 CFR 312.64(b) requires the investigator to report any SAE to the sponsor immediately. In the EU, Article 41 of the Clinical Trials Regulation sets a limit of 24 hours from knowledge of the event. The UK guidance uses the same 24-hour ceiling. The immediate report is followed by a detailed written report.

2. Record adverse events from consent to the end of the trial

Under the UK guidance, AEs, including SAEs, are recorded from signature of informed consent to the end of the trial, unless the protocol says otherwise. SARs that come to the investigator's attention after a participant's treatment has ended should still be reported.

3. Serious and severe are different judgements

Seriousness is defined by outcome: death, life-threatening, hospitalisation or its prolongation, persistent disability, or a congenital anomaly, plus important medical events. Severity describes intensity. The MHRA's example is a severe headache that is not serious. Where it is unclear whether hospitalisation occurred, the guidance says to treat the AE as serious.

4. Causality belongs to the investigator, and cannot be downgraded

The investigator usually assesses causality. Where the investigator is not a doctor or dentist, causality should be delegated to the medical member of the team unless it is part of their usual duties. The sponsor must not downgrade the investigator's assessment. If no causality assessment can be made, the SAE is treated as related.

5. Lab alert values, pregnancies and medication errors have their own rules

Clinically significant abnormal lab findings are AEs. Protocols can define lab "alert values" that must be reported on the same timeline as SAEs. Exposure during pregnancy, medication errors, misuse and abuse must be recorded and notified to the sponsor. Pregnancies are followed to outcome, because a congenital anomaly is an SAE.

6. The sponsor's clock can start at your EDC entry or a monitoring visit

The UK guidance lists email, fax, phone and entry into the EDC system as ways the investigator notifies the sponsor. An unreported SAE found during monitoring also starts the sponsor's clock that day. If an SAE sits in source notes and only reaches the sponsor at the next monitoring visit, the sponsor's 7-day window may already be under pressure.

7. Act on the safety reports the sponsor sends back

The flow runs both ways. In the US, investigators review IND safety reports from the sponsor and report unanticipated problems involving risk to participants to the IRB under 21 CFR 312.66 (FDA). Where investigators assess expectedness, the UK guidance requires the sponsor to give them the current approved reference safety information directly, not a link to a website with several versions.

By site type and by role

Site model

Where SAE reports tend to slow down

What helps

Academic medical centre

SAE found in hospital records after admission elsewhere

Clear alert routes from wards and the local lab to the study team

Dedicated research site or SMO

Several sponsors, each with its own SAE form and portal

One internal SAE log feeding each sponsor's EDC

Community or private practice site

Small team; the CRC covers several studies

Same-day EDC entry with a simple SAE form

Phase 1 unit

High event frequency and tight dose-escalation decisions

Real-time entry so the sponsor sees safety data before the next cohort

Role

Requirements that fall to them

What they should check

Principal investigators and sub-investigators

1, 3, 4, 7

Causality and seriousness are assessed and signed for every SAE

CRCs

1, 2, 5, 6

SAE forms are complete and entered the same day; lab alert values are known

CRAs

2, 6

AEs in source match EDC; unreported SAEs are escalated the day they are found

Clinical data managers

2, 5, 6

AE and SAE data in EDC reconcile with the safety database

QA auditors

1, 4, 6

Timeliness from awareness to sponsor notification is documented

Site checklist for adverse event reporting

  1. The protocol's AE collection window and any SAE reporting exemptions are known to the whole team
  2. SAEs reach the sponsor within 24 hours of the site's knowledge of the event
  3. Seriousness criteria and severity are recorded separately
  4. Every SAE has a causality assessment by the investigator, or a delegated doctor or dentist
  5. The local lab has the protocol's alert values and a contact route
  6. Pregnancies, medication errors, misuse and abuse are recorded and notified
  7. Pregnancy outcomes are followed up and reported
  8. SAEs are entered into EDC on the day they are identified
  9. IND safety reports, IB updates and RSI versions are filed in the ISF with receipt and review dates
  10. Unanticipated problems are reported to the IRB where required

How Cloudbyz EDC and Safety approach site reporting

Platforms like Cloudbyz, among others, are built so that an adverse event entered at the site is the same record the sponsor's safety team works from. How much time that saves depends on how forms, alerts and workflows are configured for each study.

Requirement

How Cloudbyz handles it

Immediate SAE reporting (1, 6)

Cloudbyz EDC includes AE and protocol deviation forms within the eCRF, with eSource for direct data entry at the site

Recording window and lab values (2, 5)

Configurable eCRFs and edit checks set up from the protocol, with lab report capture and device integrations

Seriousness and causality (3, 4)

Separate seriousness, severity and causality fields with query management when data is missing

Sponsor safety processing

With Cloudbyz Safety & Pharmacovigilance on the same platform, SAE data does not move between separate vendors' systems; the safety team handles intake, MedDRA coding and narratives

Safety reports back to site (7)

eISF and Site Portal access, so safety letters and IB updates are filed with an audit trail of when they were made available

For CRAs, the CRA Monitoring Copilot summarises adverse events and consent status in its pre-visit briefing, as counts and status only, so the monitor knows which subjects to look at first.

See the site view

Book a demo to follow an SAE from site entry in EDC to the sponsor's safety case, using a form from one of your own protocols.

Book a Cloudbyz EDC and Safety demo or email info@cloudbyz.com.